| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.605 INCHES MAXIMUM |
| CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
125.0 AC AND 50.0 DC |
| CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
1.0 AC AND 0.5 DC |
| BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC SINGLE LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
| CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
| AAQL |
BODY STYLE |
SINGLE POLE TYPE |
| THSD |
THREAD SERIES DESIGNATOR |
UNEF |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
1.200 NOMINAL AT 150 PCT SINGLE LOCATION AND 0.007 NOMINAL AT 500 PCT SINGLE LOCATION AND 0.500 NOMINAL AT 125 PCT SINGLE LOCATION AND 0.030 NOMINAL AT 300 PCT SINGLE LOCATION AND 0.100 NOMINAL AT 200 PCT SINGLE LOCATION AND 0.005 NOMINAL AT 1000 PCT SINGLE LOCATION |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
500.0 DC SINGLE LOCATION |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
| AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
| CRTK |
SWITCH TERMINAL TYPE |
PIN |
| CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
| AKPX |
POLE QUANTITY |
1 |
| CPRQ |
RESET METHOD |
MANUAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE HOOK |
| ABXD |
BUSHING LENGTH |
0.375 INCHES MAXIMUM |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC SINGLE LOCATION |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.875 INCHES NOMINAL |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| ADAQ |
BODY LENGTH |
1.500 INCHES MAXIMUM |
| ADTV |
CASE MATERIAL |
METAL |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
5.0 AMPERES DC SINGLE LOCATION |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING W/PANEL SEAL |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
| ADAT |
BODY WIDTH |
0.625 INCHES MAXIMUM |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
EXPLOSION RESISTANT AND FUNGUS RESISTANT AND DUSTPROOF AND SHOCKPROOF AND VIBRATIONPROOF |