5925-01-017-9674 ( M39019/04-209 , 352250009225 , M39019/4-209 , M39019-4-19 , MIL-PRF-39019/4 )

NSN Information
NSN FSC NIIN Item Name INC
5925-01-017-9674 5925 010179674 CIRCUIT BREAKER 0013
NSN Features
MRC Parameter Characteristics
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.950 MAXIMUM AT 200 PCT ALL LOCATIONS AND 0.055 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.240 MAXIMUM AT 400 PCT ALL LOCATIONS
ADAT BODY WIDTH 1.281 INCHES MAXIMUM
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.828 INCHES MAXIMUM
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 500.0 MILLIAMPERES AC ALL LOCATIONS AND 500.0 MILLIAMPERES DC ALL LOCATIONS
ABXD BUSHING LENGTH 0.380 INCHES MAXIMUM
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
AKPX POLE QUANTITY 2
THSD THREAD SERIES DESIGNATOR UNEF
CPRX ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO
TEST TEST DATA DOCUMENT 81349-MIL-PRF-39019 SPECIFICATION
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS AND 500.0 DC ALL LOCATIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY THD BUSHING W/PANEL SEAL
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQJX NOMINAL THREAD SIZE 0.375 INCHES
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT
CPRQ RESET METHOD MANUAL
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 120.0 AC AND 50.0 DC
TTQY TERMINAL TYPE AND QUANTITY 4 WIRE HOOK
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CRTK SWITCH TERMINAL TYPE TAB, SOLDER LUG
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE TWO
ADTV CASE MATERIAL METAL
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ADAQ BODY LENGTH 1.562 INCHES MAXIMUM
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
CMLP THREAD QUANTITY PER INCH 32
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES MAXIMUM
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-PRF-39019/4 GOVERNMENT SPECIFICATION
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 0.200 MINIMUM ALL LOCATIONS AND 7.000 MAXIMUM ALL LOCATIONS
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
M39019/04-209 81349 M 2 2 4 9Z
352250009225 H0203 A 2 5 3 ZG
M39019/4-209 81349 M 1 C AC 6 ZZ
M39019-4-19 81349 M 9 5 4 9Z
MIL-PRF-39019/4 81349 M 1 4 E ZZ
Manufacturers
Part SKU Cage Manufacturer Type Status
M39019/04-209 81349 MILITARY SPECIFICATIONS A M
352250009225 H0203 THALES NEDERLAND E A
M39019/4-209 81349 MILITARY SPECIFICATIONS A M
M39019-4-19 81349 MILITARY SPECIFICATIONS A M
MIL-PRF-39019/4 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A 0 X A 03/18/1 P 8536200040 0013
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS N I
DF N SF9EH-N F
DN 9B----- N
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P 0 X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS Z 0 EA 0 U 9B----- N
DS SMS Z 0 EA 0 U D
DF SMS Z 0 EA 0 U SF9EH-N F
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI