| BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
14000.0 AC SINGLE LOCATION AND 18000.0 DC SINGLE LOCATION |
| ADAQ |
BODY LENGTH |
6.312 INCHES NOMINAL |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
| AAQL |
BODY STYLE |
SINGLE POLE TYPE |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES AC SINGLE LOCATION AND 15.0 AMPERES DC SINGLE LOCATION |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
25.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 150.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.125 INCHES NOMINAL |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
480.0 AC SINGLE LOCATION AND 240.0 DC SINGLE LOCATION |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
5.225 INCHES NOMINAL |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.688 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
1.375 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
3.375 INCHES NOMINAL |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AKPX |
POLE QUANTITY |
1 |
| AJEC |
BOSS HEIGHT |
0.140 INCHES NOMINAL |
| CPRQ |
RESET METHOD |
MANUAL |
| CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
40.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 COMPRESSION |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
4.875 INCHES NOMINAL |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
| CPRJ |
TRIP RELEASE METHOD |
THERMAL-MAGNETIC SINGLE LOCATION |
| FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
DUSTPROOF |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |