5925-01-051-5288 5925 010515288 CIRCUIT BREAKER 0013
NSN Features
MRC Parameter Characteristics
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 28.0 DC THIRD LOCATION
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SECOND LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 480.0 AC FIRST LOCATION
AKPX POLE QUANTITY 3
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.026 INCHES NOMINAL
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
PKWT UNPACKAGED UNIT WEIGHT 2.000 POUNDS
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 480.0 AC SECOND LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
ABTD MOUNTING SLOT WIDTH 0.164 INCHES NOMINAL
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.0 AMPERES AC FIRST LOCATION
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.026 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE AND 6 SLOT
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
ADAU BODY HEIGHT 2.609 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.0 AMPERES AC SECOND LOCATION
FREQ FREQUENCY IN HERTZ 50.0 SECOND LOCATION OR 50.0 FIRST LOCATION OR 60.0 FIRST LOCATION
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
ADAQ BODY LENGTH 5.800 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 DC THIRD LOCATION
CPRQ RESET METHOD MANUAL
AJEC BOSS HEIGHT 0.218 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES DC THIRD LOCATION
THSD THREAD SERIES DESIGNATOR UNC
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.150 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.600 MAXIMUM AT 200 PCT ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 60.0 SECOND LOCATION
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC FIRST LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 THREADED STUD
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 3.547 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 32
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 4.781 INCHES NOMINAL
CQJX NOMINAL THREAD SIZE 0.138 INCHES
ADAT BODY WIDTH 3.168 INCHES MAXIMUM
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
3192043 10001 A 9 3 A TX
CF3-Z224-2W L3330 A 2 5 E ZZ
CF3-G3G3H3 74193 H 9 5 E TX
Manufacturers
Part SKU Cage Manufacturer Type Status
3192043 10001 NAVAIR AND NAVSEA MANAGED A A
CF3-Z224-2W L3330 HEINEMANN ELECTRIC CANADA INC F A
CF3-G3G3H3 74193 EATON CORP A H
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A 0 X A 1 12/02/1 P 8536200040 0013
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DN 9B----- N
DS I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P 0 X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS Z 1 EA 0 U 9B----- N
DS SMS Z 1 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI