5925-01-064-4710 ( 300-10947-1 , KB3250 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5925-01-064-4710 | 5925 | 010644710 | CIRCUIT BREAKER | 0013 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |
| ADAU | BODY HEIGHT | 4.312 INCHES NOMINAL |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| AKPX | POLE QUANTITY | 3 |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| ADAQ | BODY LENGTH | 10.000 INCHES NOMINAL |
| CPRQ | RESET METHOD | MANUAL |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 250.0 AMPERES AC ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP W/REMOTE TRIP FEATURE ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 25000.0 AC ALL LOCATIONS |
| ADAT | BODY WIDTH | 4.125 INCHES NOMINAL |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 300-10947-1 | 52515 | A | 2 | 5 | 5 | 48 | |
| KB3250 | 89946 | A | 2 | 3 | 5 | 48 |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 300-10947-1 | 52515 | ALTURDYNE CORPORATION | A | A |
| KB3250 | 89946 | EATON CORPORATION | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | A | 08/25/1 | P | 8536200040 | 0013 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| GP | ------- | C | |||
| DF | N | SF9EH-N | F | ||
| DS | N | I | |||
| DN | 9B----- | N |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | P | 0 | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| GP | SMS | Z | 0 | EA | 0 | U | ------- | C | |
| DF | SMS | J | 0 | EA | 0 | U | SF9EH-N | F | |
| DS | SMS | J | 0 | EA | 0 | U | D | ||
| DN | SMS | J | 0 | EA | 0 | U | 9B----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061300 | X | 34410 | P | 658 | Z | 9 | A | H | Z | CIRCUIT BREAKER/SWITCH NOI |