| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SECOND LOCATION |
| FREQ |
FREQUENCY IN HERTZ |
400.0 THIRD LOCATION |
| ADAQ |
BODY LENGTH |
2.500 INCHES MAXIMUM |
| AKPX |
POLE QUANTITY |
4 |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
50.0 AMPERES AC THIRD LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT THIRD LOCATION |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP FIRST LOCATION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 THREADED STUD |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.955 INCHES MAXIMUM |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC THIRD LOCATION |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC FIRST LOCATION |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT FIRST LOCATION AND 12.000 MAXIMUM AT 200 PCT FIRST LOCATION |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SECOND LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
4 TOGGLE |
| FREQ |
FREQUENCY IN HERTZ |
400.0 FIRST LOCATION |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SECOND LOCATION |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP THIRD LOCATION |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC SECOND LOCATION |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| FEAT |
SPECIAL FEATURES |
POLE 4 SHALL BE A DUMMY POLE |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, THREE, AND FOUR LINKED |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.760 INCHES MAXIMUM |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.760 INCHES MAXIMUM |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AJEC |
BOSS HEIGHT |
0.165 INCHES MAXIMUM |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC FIRST LOCATION |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
8 THREADED HOLE |
| CPRQ |
RESET METHOD |
MANUAL |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT SECOND LOCATION AND 12.000 MAXIMUM AT 200 PCT SECOND LOCATION |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.070 INCHES MAXIMUM |
| TEST |
TEST DATA DOCUMENT |
18876-+55629-002 SPECIFICATION |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC THIRD LOCATION |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
50.0 AMPERES AC FIRST LOCATION |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT THIRD LOCATION AND 12.000 MAXIMUM AT 200 PCT THIRD LOCATION |
| ADAT |
BODY WIDTH |
3.060 INCHES MAXIMUM |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY FIRST LOCATION |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 FIRST LOCATION |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| FREQ |
FREQUENCY IN HERTZ |
400.0 SECOND LOCATION |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC SECOND LOCATION |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC THIRD LOCATION |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.491 INCHES MAXIMUM |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SECOND LOCATION |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
50.0 AMPERES AC SECOND LOCATION |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SECOND LOCATION |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT FIRST LOCATION |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY THIRD LOCATION |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
EXPLOSION PROOF AND FUNGUS RESISTANT AND MOISTURE RESISTANT |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC FIRST LOCATION |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 THIRD LOCATION |