| FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
| CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC ALL LOCATIONS |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE TWO |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
20.0 AMPERES AC ALL LOCATIONS |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
| AKPX |
POLE QUANTITY |
3 |
| CPRJ |
TRIP RELEASE METHOD |
THERMAL ALL LOCATIONS |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| THSD |
THREAD SERIES DESIGNATOR |
UNS |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS ALL LOCATIONS |
| CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
-54.0 DEG CELSIUS MINIMUM ALL LOCATIONS AND 71.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
160.0 ALL LOCATIONS |
| ADTV |
CASE MATERIAL |
PLASTIC |
| CPRQ |
RESET METHOD |
MANUAL |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCK RESISTANT AND VIBRATIONPROOF |
| FEAT |
SPECIAL FEATURES |
TERMINALS SEPERATED BY BARRIERS; AMPER RATING MARKED ON ACTUATOR |
| CPRW |
ACTUATOR FUNCTION |
RESET |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH BUTTON |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.750 INCHES NOMINAL |
| CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
0.350 MINIMUM ALL LOCATIONS AND 1.400 MAXIMUM ALL LOCATIONS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 SCREW |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
205.0 AC ALL LOCATIONS |
| AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CTTC |
THREAD TOLERANCE CLASS |
2B EXTERNAL |
| ABXD |
BUSHING LENGTH |
0.250 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
1.900 INCHES NOMINAL |