| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCK RESISTANT AND HERMETICALLY SEALED AND VIBRATION RESISTANT |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
| AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
| FREQ |
FREQUENCY IN HERTZ |
60.0 ALL LOCATIONS |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
2 TOGGLE |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2000.0 AC ALL LOCATIONS AND 1000.0 AC ALL LOCATIONS |
| AKPX |
POLE QUANTITY |
2 |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| PKWT |
UNPACKAGED UNIT WEIGHT |
7.400 OUNCES |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
120.0 AC ALL LOCATIONS AND 250.0 AC ALL LOCATIONS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
4 THREADED STUD |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CBBL |
FEATURES PROVIDED |
SLIDING BAR INTERLOCK |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.475 INCHES NOMINAL |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
| CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
80.000 MINIMUM ALL LOCATIONS AND 650.000 MAXIMUM ALL LOCATIONS |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
7.5 AMPERES AC SECOND LOCATION |
| ADTV |
CASE MATERIAL |
PLASTIC |
| CPRQ |
RESET METHOD |
MANUAL |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES AC FIRST LOCATION |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
| ADAT |
BODY WIDTH |
1.500 INCHES MAXIMUM |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
| ADAQ |
BODY LENGTH |
2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
60.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 1.900 MINIMUM AT 400 PCT ALL LOCATIONS AND 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.600 MINIMUM AT 600 PCT ALL LOCATIONS AND 8.000 MAXIMUM AT 400 PCT ALL LOCATIONS AND 2.500 MAXIMUM AT 600 PCT ALL LOCATIONS |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
| AAJE |
THREAD PITCH DIAMETERS |
+0.1177/+0.1214 INCHES |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE AND TWO LINKED |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
115.0 ALL LOCATIONS |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |