| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| FREQ |
FREQUENCY IN HERTZ |
50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
20.0 AMPERES AC ALL LOCATIONS |
| AKPX |
POLE QUANTITY |
3 |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, AND THREE LINKED |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
10.0 AC |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
| CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 CONTROL |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND MOISTURE RESISTANT |
| ADAT |
BODY WIDTH |
2.240 INCHES MINIMUM AND 2.251 INCHES MAXIMUM |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC ALL LOCATIONS |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
| AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
| CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
10.000 MINIMUM ALL LOCATIONS |
| CBBL |
FEATURES PROVIDED |
SLIDING BAR INTERLOCK AND HIGH INRUSH PROTECTION |
| CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
240.0 AC ALL LOCATIONS |
| ADTV |
CASE MATERIAL |
PLASTIC |
| CPRQ |
RESET METHOD |
MANUAL |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CRTK |
SWITCH TERMINAL TYPE |
TAB, SOLDER LUG |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.500 MINIMUM AT 400 PCT ALL LOCATIONS AND 3.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 2.000 MAXIMUM AT 400 PCT ALL LOCATIONS |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
250.0 AC |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
| AJEC |
BOSS HEIGHT |
0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |