5925-01-153-7491 ( AM4-Z101-1 , 0N286855-1 , AM4-A8A2A2A18-A )

NSN Information
NSN FSC NIIN Item Name INC
5925-01-153-7491 5925 011537491 CIRCUIT BREAKER 0013
NSN Features
MRC Parameter Characteristics
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SECOND LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.409 INCHES MINIMUM AND 2.533 INCHES MAXIMUM
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
AKPX POLE QUANTITY 4
CPRH CIRCUIT PROTECTION TYPE UNDERVOLTAGE FOURTH LOCATION
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT SECOND LOCATION AND 11.000 MAXIMUM AT 200 PCT SECOND LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT THIRD LOCATION
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 30.0 DC
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP FIRST LOCATION
TTQY TERMINAL TYPE AND QUANTITY 8 THREADED STUD
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC THIRD LOCATION
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SECOND LOCATION
ADAT BODY WIDTH 2.060 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 4 TOGGLE
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.062 INCHES NOMINAL
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP THIRD LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SECOND LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, THREE, AND FOUR LINKED
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC FIRST LOCATION
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 2 ALARM
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 DC FOURTH LOCATION
ADAQ BODY LENGTH 2.500 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC SECOND LOCATION
ADTV CASE MATERIAL PLASTIC
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC FIRST LOCATION
AJEC BOSS HEIGHT 0.140 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 8 THREADED HOLE
CPRQ RESET METHOD MANUAL
FREQ FREQUENCY IN HERTZ 50.0 SECOND LOCATION OR 60.0 SECOND LOCATION
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC AND 4.0 DC
THSD THREAD SERIES DESIGNATOR UNC
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.938 INCHES NOMINAL
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT THIRD LOCATION AND 11.000 MAXIMUM AT 200 PCT THIRD LOCATION
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 50.0 THIRD LOCATION OR 60.0 THIRD LOCATION
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT FIRST LOCATION AND 11.000 MAXIMUM AT 200 PCT FIRST LOCATION
CRTK SWITCH TERMINAL TYPE TAB, SOLDER LUG
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY FIRST LOCATION
PKWT UNPACKAGED UNIT WEIGHT 12.500 OUNCES
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SECOND LOCATION
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC THIRD LOCATION
CPSM INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP FOURTH LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC THIRD LOCATION
CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS FOURTH LOCATION
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SECOND LOCATION
AEGJ SWITCH CONTACT ARRANGEMENT DOUBLE POLE, DOUBLE THROW
CMLP THREAD QUANTITY PER INCH 32
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE TWO AND INTERNAL AT POLE THREE
FREQ FREQUENCY IN HERTZ 50.0 FIRST LOCATION OR 60.0 FIRST LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT FIRST LOCATION
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY THIRD LOCATION
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC FIRST LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 102.0 DC FOURTH LOCATION
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
AM4-Z101-1 74193 H 9 5 6 TX
0N286855-1 98230 A 1 C AC 6 ZZ
AM4-A8A2A2A18-A 74193 H 9 3 E TX
Manufacturers
Part SKU Cage Manufacturer Type Status
AM4-Z101-1 74193 EATON CORP A H
0N286855-1 98230 NATIONAL SECURITY AGENCY A A
AM4-A8A2A2A18-A 74193 EATON CORP A H
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 05/16/1 P 8536200040 0013
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS I
DN 9B----- N
DA Z Q2200X- A V DISCONTINUED W/O REPLACEMENT
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DA SMS V 0 EA 0 U Z Q2200X- A
DN SMS J 0 EA 0 U 9B----- N
DS SMS J 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI