5925-01-159-6609 ( G287573-1 , G166010-1 , CD4-Z296-2W , CD4-Z296-2W , G166010-1 , CD4-Z160-1 )

NSN Information
NSN FSC NIIN Item Name INC
5925-01-159-6609 5925 011596609 CIRCUIT BREAKER 0013
NSN Features
MRC Parameter Characteristics
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC FOURTH LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT FOURTH LOCATION
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC FOURTH LOCATION
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
CPRH CIRCUIT PROTECTION TYPE UNDERVOLTAGE FIRST LOCATION
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SECOND LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SECOND LOCATION
FREQ FREQUENCY IN HERTZ 400.0 THIRD LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 60.0 AMPERES AC THIRD LOCATION
ADAT BODY WIDTH 3.096 INCHES NOMINAL
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SECOND LOCATION
AKPX POLE QUANTITY 4
TTQY TERMINAL TYPE AND QUANTITY 10 THREADED STUD
FEAT SPECIAL FEATURES FOUR TERMINALS ON POLE ONE
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC THIRD LOCATION
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.000 MINIMUM AT 200 PCT THIRD LOCATION AND 10.000 MAXIMUM AT 200 PCT THIRD LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 107.0 DC FIRST LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT THIRD LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC SECOND LOCATION
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC THIRD LOCATION
CPRJ TRIP RELEASE METHOD MAGNETIC FIRST LOCATION
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.000 MINIMUM AT 200 PCT FOURTH LOCATION AND 10.000 MAXIMUM AT 200 PCT FOURTH LOCATION
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 140.0 FOURTH LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 4 TOGGLE
ABTD MOUNTING SLOT WIDTH 0.164 INCHES NOMINAL
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 140.0 SECOND LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, THREE, AND FOUR LINKED
FREQ FREQUENCY IN HERTZ 400.0 FOURTH LOCATION
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 140.0 THIRD LOCATION
TEST TEST DATA DOCUMENT 49956-G166010 DRAWING
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.000 MINIMUM AT 200 PCT SECOND LOCATION AND 10.000 MAXIMUM AT 200 PCT SECOND LOCATION
ADTV CASE MATERIAL PLASTIC
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.032 INCHES NOMINAL
CPRQ RESET METHOD MANUAL
AJEC BOSS HEIGHT 0.218 INCHES NOMINAL
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.750 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR UNC
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC THIRD LOCATION
CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS FIRST LOCATION
CPRW ACTUATOR FUNCTION TRIP-RESET
FREQ FREQUENCY IN HERTZ 400.0 SECOND LOCATION
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 60.0 AMPERES AC FOURTH LOCATION
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY FOURTH LOCATION
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.032 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 8 THREADED HOLE AND 8 SLOT
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 3.546 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 60.0 AMPERES AC SECOND LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.609 INCHES NOMINAL
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SECOND LOCATION
ADAQ BODY LENGTH 5.844 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY THIRD LOCATION
CQJX NOMINAL THREAD SIZE 0.138 INCHES
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC FOURTH LOCATION
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
G287573-1 49956 A 9 5 5 ZZ
G166010-1 3B150 A 9 3 A TX
CD4-Z296-2W 81118 A 2 3 5 ZZ
CD4-Z296-2W L3330 A 2 5 5 ZZ
G166010-1 49956 A 9 5 A TX
CD4-Z160-1 74193 H 9 5 6 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
G287573-1 49956 RAYTHEON COMPANY A A
G166010-1 3B150 RAYTHEON TECHNICAL SERVICES COMP A A
CD4-Z296-2W 81118 EATON CORPORATION A A
CD4-Z296-2W L3330 HEINEMANN ELECTRIC CANADA INC F A
G166010-1 49956 RAYTHEON COMPANY A A
CD4-Z160-1 74193 EATON CORP A H
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 1 08/11/1 P 8536200040 0013
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DA Z Q2200X- A V DISCONTINUED W/O REPLACEMENT
DM Z 15B2--1 M 0 REVERSAL OF PHRASE CODE Z 5925-01-309-8583
DF N SF9EH-N F
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DF SMS D 0 EA 0 U SF9EH-N F
DA SMS V 0 EA 0 U Z Q2200X- A
DM SMS D 0 EA 0 U Z 15B2--1 M
DS SMS D 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI