| FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
| ABMK |
OVERALL WIDTH |
3.000 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
TRIP UNIT USED FOR TYPE AQB-A250 CIRCUIT BREAKERS ONBOARD 270 WMEC COAST GUARD VESSELS |
| AKPX |
POLE QUANTITY |
3 |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.375 INCHES NOMINAL |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS ALL LOCATIONS |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
225.0 ALL LOCATIONS |
| AAQL |
BODY STYLE |
RECTANGULAR DIMENSIONAL ENVELOPE |
| ABKW |
OVERALL HEIGHT |
3.000 INCHES NOMINAL |
| CPRJ |
TRIP RELEASE METHOD |
THERMAL-MAGNETIC ALL LOCATIONS |
| CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 SCREW |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
225.0 AMPERES AC ALL LOCATIONS |
| ABHP |
OVERALL LENGTH |
7.125 INCHES NOMINAL |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
500.0 AC ALL LOCATIONS |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE |