5925-01-281-6507 ( AP-7-1-64-102 )

NSN Information
NSN FSC NIIN Item Name INC
5925-01-281-6507 5925 012816507 CIRCUIT BREAKER 0013
NSN Features
MRC Parameter Characteristics
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.605 INCHES MAXIMUM
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCK RESISTANT AND HERMETICALLY SEALED AND VIBRATION RESISTANT
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 SINGLE LOCATION
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
ABXD BUSHING LENGTH 0.380 INCHES MAXIMUM
AAQL BODY STYLE SINGLE POLE TYPE
FREQ FREQUENCY IN HERTZ 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION
THSD THREAD SERIES DESIGNATOR UNEF
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC SINGLE LOCATION
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
TTQY TERMINAL TYPE AND QUANTITY 2 TAB W/SCREW
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQJX NOMINAL THREAD SIZE 0.375 INCHES
CPRJ TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
AAJE THREAD PITCH DIAMETERS +0.3503/+0.3537 INCHES
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 1.0 AMPERES AC SINGLE LOCATION
PKWT UNPACKAGED UNIT WEIGHT 1.800 OUNCES
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.875 INCHES NOMINAL
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
ADAQ BODY LENGTH 1.500 INCHES MAXIMUM
ADTV CASE MATERIAL METAL
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
ADAT BODY WIDTH 0.625 INCHES MAXIMUM
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.200 MINIMUM AT 200 PCT SINGLE LOCATION AND 1.700 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
AP-7-1-64-102 81541 A 2 3 E TX
Manufacturers
Part SKU Cage Manufacturer Type Status
AP-7-1-64-102 81541 SENSATA TECHNOLOGIES MARYLAND IN A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 06/29/1 P 8536200040 0013
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS Z 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI