| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
| ZZZK |
SPECIFICATION/STANDARD DATA |
95266-414-00005-08 MANUFACTURERS SOURCE CONTROL |
| CQQC |
TRIP RELEASE DUTY CYCLE |
CONTINUOUS ALL LOCATIONS |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES/RELAY TRIP ALL LOCATIONS |
| ADAQ |
BODY LENGTH |
2.500 INCHES MAXIMUM |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC SECOND LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
2 TOGGLE |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCK RESISTANT AND MOISTURE RESISTANT AND VIBRATION RESISTANT AND SALT SPRAY PROOF |
| AKPX |
POLE QUANTITY |
2 |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 THREADED STUD |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.444 INCHES MINIMUM AND 2.506 INCHES MAXIMUM |
| AJEC |
BOSS HEIGHT |
0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC SECOND LOCATION |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2000.0 DC FIRST LOCATION |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.700 MINIMUM AT 200 PCT FIRST LOCATION AND 10.000 MAXIMUM AT 200 PCT FIRST LOCATION |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
65.0 DC FIRST LOCATION |
| ADTV |
CASE MATERIAL |
PLASTIC |
| CPRQ |
RESET METHOD |
MANUAL |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.920 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
| CPRK |
AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS |
25.0 DC NOMINAL ALL LOCATIONS |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.180 MINIMUM AT 200 PCT SECOND LOCATION AND 1.800 MAXIMUM AT 200 PCT SECOND LOCATION |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
35.0 AMPERES DC FIRST LOCATION |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CQJX |
NOMINAL THREAD SIZE |
0.134 INCHES |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| FREQ |
FREQUENCY IN HERTZ |
60.0 SECOND LOCATION |
| APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| ADAT |
BODY WIDTH |
1.515 INCHES MAXIMUM |
| AAJE |
THREAD PITCH DIAMETERS |
+0.1177/+0.1214 INCHES |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE AND TWO LINKED |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES AC SECOND LOCATION |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
115.0 ALL LOCATIONS |