| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 DC FIRST LOCATION |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
140.0 DC SECOND LOCATION |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE AND 3 SLOT |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 DC SECOND LOCATION |
| AKPX |
POLE QUANTITY |
3 |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
3.475 INCHES MINIMUM AND 3.495 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
4.740 INCHES MINIMUM AND 4.760 INCHES MAXIMUM |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, AND THREE LINKED |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| AJEC |
BOSS HEIGHT |
0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS THIRD LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
25.0 AMPERES DC FIRST LOCATION |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
25.0 AMPERES DC SECOND LOCATION |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
100.0 MILLIAMPERES AC THIRD LOCATION |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM |
| ADTV |
CASE MATERIAL |
PLASTIC |
| CPRQ |
RESET METHOD |
MANUAL |
| FREQ |
FREQUENCY IN HERTZ |
60.0 THIRD LOCATION |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
21.000 MINIMUM AT 200 PCT FIRST LOCATION AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| ABTD |
MOUNTING SLOT WIDTH |
0.154 INCHES MINIMUM AND 0.174 INCHES MAXIMUM |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC THIRD LOCATION |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
3.537 INCHES MINIMUM AND 3.557 INCHES MAXIMUM |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY FIRST LOCATION |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
115.0 AC THIRD LOCATION |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| ADAT |
BODY WIDTH |
3.108 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
21.000 MINIMUM AT 200 PCT SECOND LOCATION AND 100.000 MAXIMUM AT 200 PCT SECOND LOCATION |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCK RESISTANT AND VIBRATION RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SECOND LOCATION |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
140.0 DC FIRST LOCATION |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |