| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.553 INCHES MAXIMUM |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| AKPX |
POLE QUANTITY |
3 |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
3.000 MINIMUM AT 200 PCT SECOND LOCATION AND 3.000 MINIMUM AT 200 PCT THIRD LOCATION AND 0.600 MINIMUM AT 200 PCT FIRST LOCATION AND 8.000 MAXIMUM AT 200 PCT FIRST LOCATION |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
240.0 AC SECOND LOCATION |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, AND THREE LINKED |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
240.0 AC THIRD LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.810 INCHES NOMINAL |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
20.000 MAXIMUM AT 200 PCT SECOND LOCATION |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
2.0 AMPERES AC SECOND LOCATION |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2000.0 DC FIRST LOCATION |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.016 INCHES MINIMUM AND 2.062 INCHES MAXIMUM |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC FIRST LOCATION |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
DUSTPROOF AND FUNGUS PROOF |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AJEC |
BOSS HEIGHT |
0.140 INCHES NOMINAL |
| CPRQ |
RESET METHOD |
MANUAL |
| FREQ |
FREQUENCY IN HERTZ |
60.0 THIRD LOCATION |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
2.0 AMPERES AC THIRD LOCATION |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
| ADAQ |
BODY LENGTH |
2.630 INCHES MAXIMUM |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
1.0 AMPERES DC FIRST LOCATION |
| FREQ |
FREQUENCY IN HERTZ |
60.0 SECOND LOCATION |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC SECOND LOCATION |
| APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC THIRD LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
| ADAT |
BODY WIDTH |
2.040 INCHES MINIMUM AND 2.245 INCHES MAXIMUM |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
20.000 MAXIMUM AT 200 PCT THIRD LOCATION |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-C-55629 SPECIFICATION |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |