| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 DC FOURTH LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SECOND LOCATION |
| AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
3.015 INCHES MAXIMUM |
| FREQ |
FREQUENCY IN HERTZ |
400.0 THIRD LOCATION |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC SECOND LOCATION |
| AKPX |
POLE QUANTITY |
4 |
| CPRH |
CIRCUIT PROTECTION TYPE |
UNDERVOLTAGE FOURTH LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT THIRD LOCATION |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC THIRD LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
4 TOGGLE |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
2.0 AMPERES AC FIRST LOCATION |
| FREQ |
FREQUENCY IN HERTZ |
400.0 FIRST LOCATION |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC SECOND LOCATION |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
120.0 DC FOURTH LOCATION |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, THREE, AND FOUR LINKED |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
2.0 AMPERES AC SECOND LOCATION |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCKPROOF AND CORROSION RESISTANT AND VIBRATIONPROOF AND MOISTURE RESISTANT AND FUNGUS RESISTANT |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
| PKWT |
UNPACKAGED UNIT WEIGHT |
14.800 OUNCES |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.735 INCHES MINIMUM AND 0.765 INCHES MINIMUM |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.625 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 TAB, SOLDER LUG |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
8 THREADED HOLE |
| CPRQ |
RESET METHOD |
MANUAL |
| FEAT |
SPECIAL FEATURES |
POLE FOUR IS A SWITCH |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
9.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC THIRD LOCATION |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
| ADAQ |
BODY LENGTH |
2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| FREQ |
FREQUENCY IN HERTZ |
400.0 SECOND LOCATION |
| APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC FIRST LOCATION |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
150.0 ALL LOCATIONS |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
3.0 AMPERES AC THIRD LOCATION |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT FIRST LOCATION |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC FIRST LOCATION |