| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
10.0 AMPERES AC SINGLE LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 SCREW |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
6000.0 AC SINGLE LOCATION |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.231 INCHES NOMINAL |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
| THSD |
THREAD SERIES DESIGNATOR |
UNS |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349--5809/1-10 GOVERNMENT SPECIFICATION |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AKPX |
POLE QUANTITY |
1 |
| CPRQ |
RESET METHOD |
MANUAL |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
115.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
| CQJX |
NOMINAL THREAD SIZE |
0.4375 INCHES |
| ABXD |
BUSHING LENGTH |
0.040 INCHES MINIMUM AND 0.055 INCHES MAXIMUM |
| TEST |
TEST DATA DOCUMENT |
81349-MILC5809G SPECIFICATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.281 INCHES MINIMUM AND 1.343 INCHES MAXIMUM |
| ADAT |
BODY WIDTH |
0.531 INCHES MINIMUM AND 0.593 INCHES MAXIMUM |
| FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
| ADAQ |
BODY LENGTH |
1.030 INCHES MAXIMUM |