| FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
10.0 AMPERES AC ALL LOCATIONS |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC ALL LOCATIONS |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE TWO |
| ADAQ |
BODY LENGTH |
2.265 INCHES MAXIMUM |
| AKPX |
POLE QUANTITY |
3 |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-C-55629/22 GOVERNMENT SPECIFICATION |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
240.0 DC ALL LOCATIONS |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
3 THREADED HOLE |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPRQ |
RESET METHOD |
MANUAL |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 TAB W/SCREW |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| ADAT |
BODY WIDTH |
2.232 INCHES MAXIMUM |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |