| BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
| CTTC |
THREAD TOLERANCE CLASS |
2B INTERNAL |
| ADAT |
BODY WIDTH |
1.281 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 SCREW |
| CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
EXTERNAL BETWEEN POLE ONE AND TWO |
| FREQ |
FREQUENCY IN HERTZ |
60.0 ALL LOCATIONS OR 400.0 ALL LOCATIONS |
| AKPX |
POLE QUANTITY |
2 |
| PKWT |
UNPACKAGED UNIT WEIGHT |
100.000 GRAMS |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 AC SECOND LOCATION |
| ABXD |
BUSHING LENGTH |
0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
0.75 AMPERES DC ALL LOCATIONS |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
CIRCUIT BREAKER, MAGNETIC, LOW-POWER, SEALED, TRIP FREE TWO POLE, AUXILLIARY CONTACTS |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.950 INCHES MAXIMUM |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED BUSHING |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.625 INCHES NOMINAL |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC THIRD LOCATION |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| AEGJ |
SWITCH CONTACT ARRANGEMENT |
DOUBLE POLE, DOUBLE THROW |
| ADAQ |
BODY LENGTH |
1.562 INCHES MAXIMUM |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.906 INCHES MAXIMUM |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |