| AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC SINGLE LOCATION |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
| SUPP |
SUPPLEMENTARY FEATURES |
C-SERIES TOGGLE SINGLE POLE;TERMINAL STUDS 1/4INCH-20 STAINLESS STEEL;RATED SWITCH CYLES 10,000 AT RATED AMPS AND VOLTAGE |
| AAQL |
BODY STYLE |
SINGLE POLE TYPE |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
TOGGLE CIRCUIT BREAKER |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.062 INCHES NOMINAL |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.475 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
2.500 INCHES NOMINAL |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AKPX |
POLE QUANTITY |
1 |
| FEAT |
SPECIAL FEATURES |
THIS IS A DIRECT CURRENT DEVICE-DO NOT MAKE ANY CONNECTIONS TO THE COIL SHUNT;TRIP FREE CANNOT BE HELD CLOSED AFTER TRIP;COMBINES SWITCHING AND CIRCUIT PROTECTION FOR INVERTERS/BOW THRUSTERS/WINDLASSES;PREVIOUSLY ONLY AVAILABLE IN FUSES |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
65.0 DC SINGLE LOCATION |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES DC SINGLE LOCATION |
| AGAV |
END ITEM IDENTIFICATION |
MARINE ELECTRICAL APPLICATIONS |
| ADAT |
BODY WIDTH |
0.755 INCHES NOMINAL |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
| CMLP |
THREAD QUANTITY PER INCH |
32 |