| CTYS |
CONTACT ADJUSTMENT TYPE |
EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
| CMLP |
THREAD QUANTITY PER INCH |
18 SINGLE PRESSURE CONNECTION |
| ABHP |
OVERALL LENGTH |
7.750 INCHES NOMINAL |
| CQJB |
PROOF PRESSURE |
60.00 POUNDS PER SQUARE INCH |
| CTYM |
CONTACT ADJUSTMENT RANGE |
+0.40/+17.80 ACTUATION POINT POUNDS PER SQUARE INCH AND +0.60/+18.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
125.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CTZL |
PRESSURE CONNECTOR TYPE |
PLAIN, THREADED INTERNAL SINGLE CONNECTION |
| CSCF |
TERMINAL TYPE |
SCREW |
| CQGB |
CONTACT ACTION STIMULUS |
DECREASE |
| ABKW |
OVERALL HEIGHT |
6.531 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
480.0 AC AT SEA LEVEL FIRST VOLTAGE |
| AXGY |
MOUNTING METHOD |
FLANGE AND UNTHREADED HOLE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
10.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.343 INCHES NOMINAL |
| THSD |
THREAD SERIES DESIGNATOR |
NPT SINGLE PRESSURE CONNECTION |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL W/LUGS |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
4.000 INCHES NOMINAL |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CBBL |
FEATURES PROVIDED |
TAMPER PROOF CAP |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |
| CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES SINGLE PRESSURE CONNECTION |