| CTYS |
CONTACT ADJUSTMENT TYPE |
EXTERNAL ACTUATION POINT SCREW AND EXTERNAL DEACTUATION POINT SCREW |
| ADAQ |
BODY LENGTH |
3.813 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
125.0 AC AT SEA LEVEL SECOND VOLTAGE |
| ABMK |
OVERALL WIDTH |
1.562 INCHES NOMINAL |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING |
| CQJB |
PROOF PRESSURE |
15000.00 POUNDS PER SQUARE INCH GAGE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
480.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CSCF |
TERMINAL TYPE |
WIRE LEAD |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
10.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| STYL |
STYLE DESIGNATOR |
BOURDON TUBE, OPEN FRAME |
| ABHP |
OVERALL LENGTH |
5.000 INCHES MAXIMUM |
| CTZL |
PRESSURE CONNECTOR TYPE |
FLARE, THREADED INTERNAL SINGLE CONNECTION |
| CQJX |
NOMINAL THREAD SIZE |
1.000 INCHES SINGLE THREADED BUSHING |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CMLP |
THREAD QUANTITY PER INCH |
14 SINGLE THREADED BUSHING |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |
| THSD |
THREAD SERIES DESIGNATOR |
F-PTF SINGLE THREADED BUSHING |
| CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES SINGLE PRESSURE CONNECTION |
| CTYM |
CONTACT ADJUSTMENT RANGE |
+1150.00/+12000.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE AND +600.00/+11450.00 DEACTUATION POINT POUNDS PER SQUARE INCH GAGE |