| ABHP |
OVERALL LENGTH |
1.346 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
1.346 INCHES MAXIMUM |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |
| CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
| ABMK |
OVERALL WIDTH |
1.025 INCHES MAXIMUM |
| AAQL |
BODY STYLE |
BUSHING MOUNT |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-DTL-83731 SPECIFICATION |
| THSD |
THREAD SERIES DESIGNATOR |
UNS |
| AFUR |
ACTUATOR DIAMETER |
0.430 INCHES MAXIMUM |
| AFUX |
ACTUATOR POSITION-ACTION RELATIONSHIP |
UP POSITION MAINTAINED AND DOWN POSITION MOMENTARY |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.250 INCHES MAXIMUM |
| ABXD |
BUSHING LENGTH |
0.437 INCHES NOMINAL |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| AFUQ |
ACTUATOR STYLE |
ROUND |
| CBBL |
FEATURES PROVIDED |
ACTUATOR SEAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 TAB W/SCREW |
| ABKW |
OVERALL HEIGHT |
2.769 INCHES NOMINAL |
| AFUY |
ACTUATOR POSITION-LOCKING RELATIONSHIP |
UP POSITION LOCKED IN AND DOWN POSITION NO LOCKING ACTION |
| CXQR |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
18.000 AMPERES RESISTIVE DC AND 5.000 AMPERES LAMP DC AND 10.000 AMPERES INDUCTIVE DC AND 11.000 AMPERES RESISTIVE AC AND 8.000 AMPERES INDUCTIVE AC AND 2.000 AMPERES LAMP AC |
| ZZZK |
SPECIFICATION/STANDARD DATA |
96906-MS25126 GOVERNMENT STANDARD |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| AFUS |
ACTUATOR HEIGHT |
1.082 INCHES NOMINAL |