| CTZL |
PRESSURE CONNECTOR TYPE |
FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| AWTN |
OPERATING TEMP RATING |
-65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
| AXGY |
MOUNTING METHOD |
BRACKET AND UNTHREADED HOLE |
| CQJX |
NOMINAL THREAD SIZE |
0.500 INCHES SINGLE PRESSURE CONNECTION |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE |
| ABMK |
OVERALL WIDTH |
3.600 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
2.000 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CQGB |
CONTACT ACTION STIMULUS |
DECREASE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| ABPM |
BODY DIAMETER |
3.500 INCHES NOMINAL |
| CTYX |
CONTACT STIMULUS RATING |
700.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 500.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
2.875 INCHES NOMINAL |
| CQJB |
PROOF PRESSURE |
4500.00 POUNDS PER SQUARE INCH |
| THSD |
THREAD SERIES DESIGNATOR |
NPT SINGLE PRESSURE CONNECTION |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL W/MOUNTING LUGS |
| ABKV |
OUTSIDE DIAMETER |
0.500 INCHES NOMINAL SINGLE CONNECTION |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
EXPLOSION PROOF |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.218 INCHES NOMINAL |
| ABHP |
OVERALL LENGTH |
2.516 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| AJZC |
PRESSURE SWITCH TYPE |
DIFFERENTIAL |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS |