| CTZL |
PRESSURE CONNECTOR TYPE |
FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| CTYX |
CONTACT STIMULUS RATING |
11.50 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH ABSOLUTE AND 13.50 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH ABSOLUTE AND 2.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH ABSOLUTE |
| AXGY |
MOUNTING METHOD |
INLET CONNECTION |
| FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| ABKV |
OUTSIDE DIAMETER |
0.438 INCHES NOMINAL SINGLE CONNECTION |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CSCF |
TERMINAL TYPE |
WIRE HOOK |
| CQGB |
CONTACT ACTION STIMULUS |
DECREASE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| AAJD |
THREAD CLASS |
3A SINGLE PRESSURE CONNECTION |
| ASDB |
WIDTH ACROSS FLATS |
0.900 INCHES NOMINAL |
| CQJB |
PROOF PRESSURE |
40.00 POUNDS PER SQUARE INCH |
| CSCC |
SENSING ELEMENT BURST PRESSURE |
45.00 POUNDS PER SQUARE INCH |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| AWTN |
OPERATING TEMP RATING |
-55.0 DEG CELSIUS MINIMUM AND 95.0 DEG CELSIUS MAXIMUM |
| AASA |
THREAD LENGTH |
0.550 INCHES NOMINAL SINGLE PRESSURE CONNECTION |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| AJZC |
PRESSURE SWITCH TYPE |
ABSOLUTE |
| ABHP |
OVERALL LENGTH |
2.300 INCHES MAXIMUM |
| CQJX |
NOMINAL THREAD SIZE |
0.438 INCHES SINGLE PRESSURE CONNECTION |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE PRESSURE CONNECTION |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS |