| CTZL |
PRESSURE CONNECTOR TYPE |
FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| CMLP |
THREAD QUANTITY PER INCH |
18 SINGLE PRESSURE CONNECTION |
| CTYX |
CONTACT STIMULUS RATING |
11.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 7.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 3.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
| ADAQ |
BODY LENGTH |
1.000 INCHES MAXIMUM |
| ADAV |
OVERALL DIAMETER |
0.875 INCHES MAXIMUM |
| MEDA |
MEDIA FOR WHICH DESIGNED |
LIQUID |
| CQJB |
PROOF PRESSURE |
120.00 POUNDS PER SQUARE INCH |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| AXGY |
MOUNTING METHOD |
CLAMP |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| AAJD |
THREAD CLASS |
3A SINGLE PRESSURE CONNECTION |
| ABHP |
OVERALL LENGTH |
2.250 INCHES MINIMUM AND 2.370 INCHES MAXIMUM |
| AWTN |
OPERATING TEMP RATING |
-65.0 DEG FAHRENHEIT MINIMUM AND 200.0 DEG FAHRENHEIT MAXIMUM |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| AASA |
THREAD LENGTH |
0.275 INCHES NOMINAL SINGLE PRESSURE CONNECTION |
| ABKV |
OUTSIDE DIAMETER |
0.563 INCHES NOMINAL SINGLE CONNECTION |
| CTHF |
CONTACT LOAD CURRENT RATING |
100.0 MILLIAMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| CQJX |
NOMINAL THREAD SIZE |
0.5625 INCHES SINGLE PRESSURE CONNECTION |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE PRESSURE CONNECTION |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
WATERTIGHT |
| CSCC |
SENSING ELEMENT BURST PRESSURE |
180.00 POUNDS PER SQUARE INCH |