| ABJP |
POWER CABLE LENGTH |
ANY ACCEPTABLE |
| BBJX |
MOUNTING POSITION |
HORIZONTAL |
| BJKG |
RELAY |
NOT INCLUDED |
| BJKC |
MAXIMUM CURRENT RATING |
10.0 AMPERES RESISTIVE LOAD |
| APGW |
CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.0 AMPERES RESISTIVE LOAD |
| ALSF |
INTERNAL BATTERY ACCOMMODATION |
NOT INCLUDED |
| AGBD |
ELECTRICAL CONNECTION TYPE |
CABLE |
| ABHP |
OVERALL LENGTH |
13.250 INCHES NOMINAL |
| ACYN |
AC VOLTAGE RATING |
230.0 VOLTS NOMINAL |
| BJKD |
CONTACT ARRANGEMENT |
SINGLE THROW,ON AT LOW LEVEL |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| BJKH |
LIQUID TYPE FOR WHICH DESIGNED |
GASOLINE AND LUBRICATING OIL |
| ABKW |
OVERALL HEIGHT |
9.750 INCHES NOMINAL |
| BJKP |
MOUNTING DIMENSIONS |
MTD ON 1 IN. IPS WITH 1/2 IN. CONDUIT CONNECTION |
| APGY |
VOLTAGE RATING AT MAXIMUM RATED CURRENT |
115.0 VOLTS |
| BJKN |
FLOAT EFFECTIVE TRAVEL |
ANY ACCEPTABLE |
| ACYR |
DC VOLTAGE RATING |
230.0 VOLTS NOMINAL |
| BJKQ |
TANK INSERTION LENGTH |
3.500 INCHES MINIMUM AND 4.250 INCHES MAXIMUM |
| AXGY |
MOUNTING METHOD |
THREAD |
| ABMK |
OVERALL WIDTH |
6.000 INCHES NOMINAL |
| AWTN |
OPERATING TEMP RATING |
425.0 DEG FAHRENHEIT MAXIMUM |
| AWAE |
FLOAT QUANTITY |
1 |
| FAAZ |
PHASE |
SINGLE |