| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
| AKBY |
TEMP SENSING ELEMENT TYPE |
CAPILLARY TUBE-BULB |
| ABHP |
OVERALL LENGTH |
9.062 INCHES NOMINAL |
| CBBL |
FEATURES PROVIDED |
ELECTRICAL ACCESS PORT |
| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
3.625 INCHES NOMINAL |
| CSCF |
TERMINAL TYPE |
SCREW |
| AEVT |
CAPILLARY TUBE LENGTH |
25.0 INCHES NOMINAL |
| AXGY |
MOUNTING METHOD |
FLANGE AND UNTHREADED HOLE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| ADAQ |
BODY LENGTH |
4.250 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
480.0 AC AT SEA LEVEL SINGLE VOLTAGE |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.281 INCHES NOMINAL |
| CTYS |
CONTACT ADJUSTMENT TYPE |
INTERNAL DEACTUATION POINT SCREW AND INTERNAL ACTUATION POINT SCREW |
| ABMK |
OVERALL WIDTH |
3.875 INCHES NOMINAL |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
EXPLOSION PROOF |
| CTYX |
CONTACT STIMULUS RATING |
175.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 173.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| AFDV |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS |
3.000 INCHES NOMINAL |
| CTYM |
CONTACT ADJUSTMENT RANGE |
+0.00/+400.00 ACTUATION POINT DEGREES FAHRENHEIT AND +0.00/+400.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CQYJ |
MOUNTING FACILITY PATTERN |
FOUR POSITION RECTANGULAR |
| AWTN |
OPERATING TEMP RATING |
20.0 DEG FAHRENHEIT MINIMUM AND 180.0 DEG FAHRENHEIT MAXIMUM |
| AEVV |
BULB DIAMETER |
0.375 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| ABKW |
OVERALL HEIGHT |
4.250 INCHES NOMINAL |
| AEVU |
BULB LENGTH |
2.969 INCHES NOMINAL |