| CSCF |
TERMINAL TYPE |
QUICK DISCONNECT, MALE |
| AXGY |
MOUNTING METHOD |
BRACKET |
| CTYX |
CONTACT STIMULUS RATING |
9.00 ACTUATION POINT NOMINAL INCHES OF WATER AND 6.00 DEACTUATION POINT NOMINAL INCHES OF WATER AND 3.00 DIFFERENTIAL POINT NOMINAL INCHES OF WATER |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
125.0 AC AT SEA LEVEL SECOND VOLTAGE |
| ADAQ |
BODY LENGTH |
1.953 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| ABHP |
OVERALL LENGTH |
2.891 INCHES NOMINAL |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| CTHF |
CONTACT LOAD CURRENT RATING |
10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| ADAV |
OVERALL DIAMETER |
3.219 INCHES NOMINAL |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
0.813 INCHES NOMINAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
250.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |