| CTHF |
CONTACT LOAD CURRENT RATING |
5.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CMLP |
THREAD QUANTITY PER INCH |
18 SINGLE PRESSURE CONNECTION |
| AXGY |
MOUNTING METHOD |
BRACKET |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
2.000 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
125.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
230.0 DC AT SEA LEVEL THIRD VOLTAGE |
| ABMK |
OVERALL WIDTH |
4.563 INCHES NOMINAL |
| CSCF |
TERMINAL TYPE |
WIRE LEAD |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE |
| THSD |
THREAD SERIES DESIGNATOR |
NPT SINGLE PRESSURE CONNECTION |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
460.0 AC AT SEA LEVEL FIRST VOLTAGE |
| ABHP |
OVERALL LENGTH |
6.688 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
3.125 INCHES NOMINAL |
| CTYM |
CONTACT ADJUSTMENT RANGE |
+35.00/+400.00 ACTUATION POINT POUNDS PER SQUARE INCH |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
24.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
300.0 MILLIAMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES SINGLE PRESSURE CONNECTION |