| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| AKBY |
TEMP SENSING ELEMENT TYPE |
CAPILLARY TUBE-BULB |
| AWTN |
OPERATING TEMP RATING |
-30.0 DEG FAHRENHEIT MINIMUM AND 600.0 DEG FAHRENHEIT MAXIMUM |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE |
| AXGY |
MOUNTING METHOD |
FLUSH |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
125.0 AC AT SEA LEVEL SECOND VOLTAGE |
| ABMK |
OVERALL WIDTH |
2.500 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| ABKW |
OVERALL HEIGHT |
2.500 INCHES NOMINAL |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE |
| CTHF |
CONTACT LOAD CURRENT RATING |
35.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
1.750 INCHES NOMINAL |
| CTYM |
CONTACT ADJUSTMENT RANGE |
+200.00/+575.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
250.0 AC AT SEA LEVEL FIRST VOLTAGE |
| AEVT |
CAPILLARY TUBE LENGTH |
36.000 INCHES NOMINAL |
| FREQ |
FREQUENCY IN HERTZ |
60.0 SECOND VOLTAGE |
| CTYS |
CONTACT ADJUSTMENT TYPE |
EXTERNAL ACTUATION POINT KNOB WITH SCALE |
| ABHP |
OVERALL LENGTH |
3.906 INCHES NOMINAL |
| CSCF |
TERMINAL TYPE |
TAB W/SCREW |