| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
2.625 INCHES NOMINAL |
| AXGY |
MOUNTING METHOD |
BRACKET |
| AFDV |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS |
2.000 INCHES NOMINAL |
| CQJX |
NOMINAL THREAD SIZE |
0.4375 INCHES SINGLE PRESSURE CONNECTION |
| ABHP |
OVERALL LENGTH |
5.250 INCHES NOMINAL |
| CMLP |
THREAD QUANTITY PER INCH |
20 SINGLE PRESSURE CONNECTION |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
0.5 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT NOT ADJUSTABLE |
| ABKW |
OVERALL HEIGHT |
3.650 INCHES NOMINAL |
| CTYX |
CONTACT STIMULUS RATING |
1.00 DIFFERENTIAL POINT NOMINAL INCHES OF WATER |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| ABMK |
OVERALL WIDTH |
5.250 INCHES NOMINAL |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| CQYJ |
MOUNTING FACILITY PATTERN |
FOUR POSITION RECTANGULAR |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE PRESSURE CONNECTION |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |