5930-00-570-9888 ( 12925 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5930-00-570-9888 | 5930 | 005709888 | SWITCH,LIQUID LEVEL | 3718 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| AWAE | FLOAT QUANTITY | 2 |
| BJKH | LIQUID TYPE FOR WHICH DESIGNED | VARIOUS FUELS |
| BJKN | FLOAT EFFECTIVE TRAVEL | 3.000 INCHES MINIMUM AND 8.000 INCHES MAXIMUM |
| ABJP | POWER CABLE LENGTH | 360.000 INCHES NOMINAL |
| BJKG | RELAY | INCLUDED |
| BBJX | MOUNTING POSITION | VERTICAL |
| ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
| APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.5 AMPERES RESISTIVE LOAD AND 0.25 AMPERES RESISTIVE LOAD |
| ACYN | AC VOLTAGE RATING | 110.0 VOLTS NOMINAL |
| AGBD | ELECTRICAL CONNECTION TYPE | CABLE |
| ACYR | DC VOLTAGE RATING | 8.32 VOLTS NOMINAL |
| ADAV | OVERALL DIAMETER | 2.937 INCHES NOMINAL |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| ABHP | OVERALL LENGTH | 396.000 INCHES NOMINAL |
| BJKD | CONTACT ARRANGEMENT | 2 SINGLE POLE,SINGLE THROW |
| AFLW | ACTUATION METHOD | BUOYANCY |
| AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 350.0 DEG FAHRENHEIT MAXIMUM |
| AXGY | MOUNTING METHOD | THREAD |
| ACYN | AC VOLTAGE RATING | 220.0 VOLTS NOMINAL |
| BJKP | MOUNTING DIMENSIONS | MTD BY 2.000 IN. NPT 2A |
| BJKQ | TANK INSERTION LENGTH | 393.000 INCHES NOMINAL |
| FAAZ | PHASE | SINGLE |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 12925 | 04034 | A | 2 | 3 | 1 | CX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 12925 | 04034 | GEMS SENSORS INC. | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| U | X | A | 1 | 03/23/1 | P | 8413919520 | 3718 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | D | 3B----- | N | ||
| DS | F | I | X | FORMERLY 6680-00-570-9888 |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | U | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | Z | 1 | EA | 0 | U | D | ||
| DN | SMS | Z | 1 | EA | 0 | U | 3B----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061300 | X | 34410 | P | 658 | Z | 9 | A | H | Z | CIRCUIT BREAKER/SWITCH NOI |