| CTYX |
CONTACT STIMULUS RATING |
3.50 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH ABSOLUTE |
| CMLP |
THREAD QUANTITY PER INCH |
27 SINGLE PRESSURE CONNECTION |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES ALL THREADED HOLE |
| ABMK |
OVERALL WIDTH |
2.500 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
10.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
1.500 INCHES NOMINAL |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT NOT ADJUSTABLE |
| ABHP |
OVERALL LENGTH |
4.297 INCHES NOMINAL |
| THSD |
THREAD SERIES DESIGNATOR |
NPT SINGLE PRESSURE CONNECTION |
| CTYM |
CONTACT ADJUSTMENT RANGE |
+58.70/+62.20 ACTUATION POINT INCHES OF MERCURY |
| CMLP |
THREAD QUANTITY PER INCH |
32 ALL THREADED HOLE |
| AJZC |
PRESSURE SWITCH TYPE |
ABSOLUTE |
| AFDV |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS |
1.500 INCHES NOMINAL |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| CQYJ |
MOUNTING FACILITY PATTERN |
FOUR POSITION RECTANGULAR |
| CQJX |
NOMINAL THREAD SIZE |
0.125 INCHES SINGLE PRESSURE CONNECTION |
| AXGY |
MOUNTING METHOD |
BASE AND THREADED HOLE |
| ABKW |
OVERALL HEIGHT |
2.594 INCHES NOMINAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |