| AFWH |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH |
4.219 INCHES NOMINAL |
| AFWC |
HOUSING HEIGHT |
2.062 INCHES NOMINAL |
| AFWJ |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO WIDTH |
1.812 INCHES NOMINAL |
| AFGK |
ACTUATOR LENGTH |
1.500 INCHES NOMINAL |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CSJN |
SWITCH ACTUATING FORCE |
40.0 INCH-OUNCES MINIMUM AND 133.0 INCH-OUNCES MAXIMUM |
| AAQL |
BODY STYLE |
HOLE MOUNTED |
| CRRM |
SWITCH RELEASE FORCE |
16.0 INCH-OUNCES MAXIMUM |
| AFWD |
HOUSING LENGTH |
4.940 INCHES NOMINAL |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
250.0 AC AND 250.0 DC |
| AFWE |
HOUSING WIDTH |
2.312 INCHES NOMINAL |
| AFUW |
ACTUATOR ROLLER WIDTH |
0.250 INCHES NOMINAL |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
DRIPTIGHT |
| TEST |
TEST DATA DOCUMENT |
10001-1637024 DRAWING |
| AFUQ |
ACTUATOR STYLE |
ROLLER ARM |
| CBBL |
FEATURES PROVIDED |
ACTUATOR SEAL |
| ABMK |
OVERALL WIDTH |
3.250 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
1.560 INCHES NOMINAL |
| ABHP |
OVERALL LENGTH |
4.940 INCHES NOMINAL |
| CXQR |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
15.000 AMPERES RESISTIVE AC AND 500.000 MILLIAMPERES RESISTIVE DC AND 3.000 AMPERES INDUCTIVE AC |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
3 POLE, SINGLE THROW, DOUBLE MAKE, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT |
| AFUV |
ACTUATOR ROLLER DIAMETER |
0.750 INCHES NOMINAL |