5930-00-845-2995 ( A10-1570 , A30-262 , RJS3163 , 32177 , A10-1570 , 9041002-02 , A30-262 , 32177 , 5000-7-11 , RJS3163 , A30-2239 )

NSN Information
NSN FSC NIIN Item Name INC
5930-00-845-2995 5930 008452995 SWITCH,THERMOSTATIC 0045
NSN Features
MRC Parameter Characteristics
CTHF CONTACT LOAD CURRENT RATING 16.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
AKBY TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
CTZB CONTACT VOLTAGE RATING IN VOLTS 120.0 AC AT SEA LEVEL SECOND VOLTAGE
ABMK OVERALL WIDTH 1.294 INCHES NOMINAL
CTHF CONTACT LOAD CURRENT RATING 8.3 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CTYX CONTACT STIMULUS RATING 43.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT
AEVU BULB LENGTH 4.000 INCHES NOMINAL
CQGB CONTACT ACTION STIMULUS INCREASE
CTYC CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE
ABKW OVERALL HEIGHT 1.922 INCHES NOMINAL
CTZB CONTACT VOLTAGE RATING IN VOLTS 240.0 AC AT SEA LEVEL FIRST VOLTAGE
CMLP THREAD QUANTITY PER INCH 32 ALL THREADED HOLE
FEAT SPECIAL FEATURES TWO MTG HOLES SPACED 2.187 IN. C TO C
ABHP OVERALL LENGTH 2.562 INCHES NOMINAL
CQJX NOMINAL THREAD SIZE 0.164 INCHES ALL THREADED HOLE
AEVT CAPILLARY TUBE LENGTH 36.000 INCHES NOMINAL
AXGY MOUNTING METHOD BRACKET AND THREADED HOLE
AEVV BULB DIAMETER 0.375 INCHES NOMINAL
CSCF TERMINAL TYPE TAB W/SCREW
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
A10-1570 49742 R 9 5 3 TX
A30-262 49742 R 9 5 3 TX
RJS3163 50992 A 1 C 9F 5 ZZ
32177 50992 A 1 C 9F 5 ZZ
A10-1570 50992 A 1 C 9F 5 ZZ
9041002-02 30130 A 1 C AC 6 ZZ
A30-262 50992 A 1 C 9F 5 ZZ
32177 49742 R 9 5 2 SE
5000-7-11 06178 A 2 3 X XX
RJS3163 49742 R 9 5 2 SE
A30-2239 50992 A 1 C AC 6 ZZ
Manufacturers
Part SKU Cage Manufacturer Type Status
A10-1570 49742 RANCO MANAGEMENT CORP A R
A30-262 49742 RANCO MANAGEMENT CORP A R
RJS3163 50992 RANCO INC A A
32177 50992 RANCO INC A A
A10-1570 50992 RANCO INC A A
9041002-02 30130 MILE HIGH EQUIPMENT COMPANY A A
A30-262 50992 RANCO INC A A
32177 49742 RANCO MANAGEMENT CORP A R
5000-7-11 06178 PUREGAS LLC A A
RJS3163 49742 RANCO MANAGEMENT CORP A R
A30-2239 50992 RANCO INC A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 01/01/1 P 9032100000 0045
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DM Z 12B2--- M
DS N I
DA Z Q2200X- A
DF N SF9EH-N F
GP ------- C
DN 9B----- N
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DA SMS J 1 EA 0 U Z Q2200X- A
GP SMS J 1 EA 0 U ------- C
DM SMS J 1 EA 0 U Z 12B2--- M
DF SMS J 1 EA 0 U SF9EH-N F
DS SMS J 1 EA 0 U D
DN SMS J 1 EA 0 U 9B----- N
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI