| AXGY |
MOUNTING METHOD |
INLET CONNECTION |
| CTHF |
CONTACT LOAD CURRENT RATING |
7.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 7.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| CTYX |
CONTACT STIMULUS RATING |
850.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 850.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 0.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
| CSCC |
SENSING ELEMENT BURST PRESSURE |
6000.00 POUNDS PER SQUARE INCH GAGE |
| ABHP |
OVERALL LENGTH |
4.000 INCHES MAXIMUM |
| MEDA |
MEDIA FOR WHICH DESIGNED |
LIQUID |
| CTHF |
CONTACT LOAD CURRENT RATING |
4.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 2.5 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
230.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CQJB |
PROOF PRESSURE |
4500.00 POUNDS PER SQUARE INCH GAGE |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 AC AT SEA LEVEL SECOND VOLTAGE |
| ADAV |
OVERALL DIAMETER |
1.750 INCHES MAXIMUM |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| AJZC |
PRESSURE SWITCH TYPE |
DIFFERENTIAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |