| AFWD |
HOUSING LENGTH |
3.640 INCHES MINIMUM AND 3.760 INCHES MAXIMUM |
| AFWH |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH |
2.295 INCHES MINIMUM AND 2.325 INCHES MAXIMUM |
| CSJN |
SWITCH ACTUATING FORCE |
48.0 INCH-OUNCES MAXIMUM |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| AAQL |
BODY STYLE |
HOLE MOUNTED |
| AFWE |
HOUSING WIDTH |
1.540 INCHES MINIMUM AND 1.600 INCHES MAXIMUM |
| CXQQ |
ACTUATOR MOVEMENT |
30.0 OVERTRAVEL DEGREES MINIMUM AND 20.0 PRETRAVEL DEGREES MAXIMUM AND 12.0 DIFFERENTIAL DEGREES MAXIMUM |
| CRRM |
SWITCH RELEASE FORCE |
8.0 INCH-OUNCES MINIMUM |
| AFWJ |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO WIDTH |
1.175 INCHES MINIMUM AND 2.205 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
4 SCREW |
| AFWC |
HOUSING HEIGHT |
1.532 INCHES MINIMUM AND 1.592 INCHES MAXIMUM |
| AFUQ |
ACTUATOR STYLE |
ROLLER ARM |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| AFUW |
ACTUATOR ROLLER WIDTH |
0.280 INCHES NOMINAL |
| CBBL |
FEATURES PROVIDED |
ACTUATOR SEAL |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
460.0 AC AND 230.0 DC |
| CXQR |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
400.000 MILLIAMPERES RESISTIVE DC AND 10.000 AMPERES RESISTIVE AC |
| AFUV |
ACTUATOR ROLLER DIAMETER |
0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED SINGLE SWITCH UNIT |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
INDUSTRIAL USE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |