| ABPM |
BODY DIAMETER |
0.500 INCHES NOMINAL |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
| AXGY |
MOUNTING METHOD |
FLANGE |
| CTYS |
CONTACT ADJUSTMENT TYPE |
EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
| ADAQ |
BODY LENGTH |
2.750 INCHES MAXIMUM |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE |
| CSCF |
TERMINAL TYPE |
TAB, SOLDER LUG |
| CTYM |
CONTACT ADJUSTMENT RANGE |
+32.00/+300.00 ACTUATION POINT DEGREES FAHRENHEIT AND +30.00/+298.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CTHF |
CONTACT LOAD CURRENT RATING |
1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| ABHP |
OVERALL LENGTH |
3.062 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| AKBY |
TEMP SENSING ELEMENT TYPE |
INTERNAL SENSOR |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
32.0 DC AT SEA LEVEL SECOND VOLTAGE |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
0.750 INCHES NOMINAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| CTYX |
CONTACT STIMULUS RATING |
70.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 68.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |