| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CXQQ |
ACTUATOR MOVEMENT |
60.0 OVERTRAVEL DEGREES MINIMUM AND 15.0 PRETRAVEL DEGREES MAXIMUM AND 7.0 DIFFERENTIAL DEGREES MAXIMUM |
| AFWJ |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO WIDTH |
1.156 INCHES NOMINAL |
| AFWD |
HOUSING LENGTH |
4.685 INCHES NOMINAL |
| CXQR |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
400.000 MILLIAMPERES RESISTIVE DC AND 150.000 MILLIAMPERES INDUCTIVE DC AND 600.000 MILLIAMPERES INDUCTIVE AC |
| AFWC |
HOUSING HEIGHT |
1.875 INCHES NOMINAL |
| CSJN |
SWITCH ACTUATING FORCE |
64.0 INCH-OUNCES MAXIMUM |
| AFWE |
HOUSING WIDTH |
1.875 INCHES NOMINAL |
| AFWH |
CENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH |
2.344 INCHES NOMINAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
2 TWO CIRCUIT, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
CORROSION RESISTANT AND OILTIGHT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 SCREW |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
600.0 AC AND 240.0 DC |