| CQMK |
CONTACT VOLTAGE RATING IN VOLTS |
125.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
| CSLC |
SWITCH ACTUATOR POSITIONING INCREMENT |
45.0 DEGREES SINGLE ACTUATOR |
| CQYJ |
MOUNTING FACILITY PATTERN |
ISOSCELES TRIANGLE 2ND MOUNTING FACILITY |
| AAJD |
THREAD CLASS |
2B 2ND MOUNTING FACILITY |
| CQMK |
CONTACT VOLTAGE RATING IN VOLTS |
500.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
| AFDV |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS |
2.188 INCHES NOMINAL 2ND MOUNTING FACILITY |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING 1ST MOUNTING FACILITY |
| AASA |
THREAD LENGTH |
0.375 INCHES NOMINAL 1ST MOUNTING FACILITY |
| THSD |
THREAD SERIES DESIGNATOR |
UNEF 1ST MOUNTING FACILITY |
| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
2.000 INCHES NOMINAL 2ND MOUNTING FACILITY |
| CQQT |
SWITCH ACTUATOR MOMENTARY POSITION |
CLOCKWISE SINGLE ACTUATOR |
| AKPX |
POLE QUANTITY |
2 EACH SECTION PERIPHERY |
| CTHF |
CONTACT LOAD CURRENT RATING |
5.0 AMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
| AGAV |
END ITEM IDENTIFICATION |
PANEL CONTROL 96169 |
| ABKW |
OVERALL HEIGHT |
2.906 INCHES NOMINAL |
| CSHW |
CONTACT SWITCHING ACTION |
BREAKS BEFORE MAKES EACH SECTION PERIPHERY |
| AXGY |
MOUNTING METHOD |
BRACKET 2ND MOUNTING FACILITY AND UNTHREADED HOLE 2ND MOUNTING FACILITY |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.221 INCHES NOMINAL 2ND MOUNTING FACILITY |
| CRJH |
SWITCH ACTUATOR INDEXING POSITION QUANTITY |
8 SINGLE ACTUATOR |
| AKPY |
THROW QUANTITY |
8 EACH SECTION PERIPHERY |
| AFBH |
INDIVIDUAL SECTION QUANTITY |
10 |
| AJZE |
SWITCH CONTACT BASIC DESIGN |
NONPILE-UP SYMMETRICAL |
| CBBL |
FEATURES PROVIDED |
ACTUATOR KNOB |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
EXPLOSION PROOF |
| ABMK |
OVERALL WIDTH |
2.812 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
20.0 AMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL |
| FEAT |
SPECIAL FEATURES |
TWO STOP SCREWS SUPPLIED FOR SWITCH LIMITING |
| STYL |
STYLE DESIGNATOR |
TAP, CIRCUIT SELECTOR |
| ABHP |
OVERALL LENGTH |
10.563 INCHES NOMINAL |
| AAJD |
THREAD CLASS |
2A 1ST MOUNTING FACILITY |
| AFDT |
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
1.000 INCHES NOMINAL 2ND MOUNTING FACILITY |
| CTDN |
SWITCH ACTUATOR STOP DEVICE TYPE |
FIXED STOP SINGLE ACTUATOR |
| AFCQ |
KNOB MANUFACTURER CODE |
82121 |
| CQJX |
NOMINAL THREAD SIZE |
0.625 INCHES 1ST MOUNTING FACILITY |
| CSCF |
TERMINAL TYPE |
TAB W/SCREW |