| AKBY |
TEMP SENSING ELEMENT TYPE |
CAPILLARY TUBE-BULB |
| CBBL |
FEATURES PROVIDED |
ELECTRICAL ACCESS PORT |
| CSCF |
TERMINAL TYPE |
SCREW |
| ABHP |
OVERALL LENGTH |
4.250 INCHES NOMINAL |
| AXGY |
MOUNTING METHOD |
FLANGE AND UNTHREADED HOLE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| AEVU |
BULB LENGTH |
6.688 INCHES NOMINAL |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.250 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
9.062 INCHES NOMINAL |
| CTYS |
CONTACT ADJUSTMENT TYPE |
INTERNAL DEACTUATION POINT SCREW AND INTERNAL ACTUATION POINT SCREW |
| AFDV |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS |
3.625 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
2.875 INCHES NOMINAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| AWTN |
OPERATING TEMP RATING |
-40.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
| ADAU |
BODY HEIGHT |
4.250 INCHES NOMINAL |
| CQYJ |
MOUNTING FACILITY PATTERN |
FOUR POSITION RECTANGULAR |
| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
3.000 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
REFRIGERATOR |
| AEVV |
BULB DIAMETER |
0.375 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CTYM |
CONTACT ADJUSTMENT RANGE |
-40.00/+120.00 ACTUATION POINT DEGREES FAHRENHEIT AND -40.00/+120.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
250.0 AC AT SEA LEVEL SINGLE VOLTAGE |
| AEVT |
CAPILLARY TUBE LENGTH |
72.0 INCHES NOMINAL |