| CTHF |
CONTACT LOAD CURRENT RATING |
4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
| CQJX |
NOMINAL THREAD SIZE |
0.750 INCHES SINGLE THREADED HOLE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
550.0 DC AT SEA LEVEL EIGHTH VOLTAGE |
| AKBY |
TEMP SENSING ELEMENT TYPE |
CAPILLARY TUBE-BULB |
| AXGY |
MOUNTING METHOD |
BRACKET AND UNTHREADED HOLE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE, PRESET |
| AEVV |
BULB DIAMETER |
0.688 INCHES NOMINAL |
| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
2.406 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
440.0 DC AT SEA LEVEL SEVENTH VOLTAGE |
| ABMK |
OVERALL WIDTH |
5.188 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| AEVT |
CAPILLARY TUBE LENGTH |
3.000 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
230.0 DC AT SEA LEVEL SIXTH VOLTAGE |
| CSCF |
TERMINAL TYPE |
SCREW |
| ADAQ |
BODY LENGTH |
2.750 INCHES NOMINAL |
| CQYJ |
MOUNTING FACILITY PATTERN |
OBTUSE TRIANGLE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 DC AT SEA LEVEL FIFTH VOLTAGE |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR |
| ABKW |
OVERALL HEIGHT |
2.812 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
DUSTPROOF AND VIBRATION RESISTANT AND WATERTIGHT |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
230.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE |
| AEVU |
BULB LENGTH |
3.000 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE |
| THSD |
THREAD SERIES DESIGNATOR |
NPT SINGLE THREADED HOLE |
| ADAU |
BODY HEIGHT |
2.688 INCHES NOMINAL |
| FEAT |
SPECIAL FEATURES |
WEAPON SYSTEM ESSENTIAL |
| AFDU |
INTERMEDIATE HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
0.656 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
550.0 AC AT SEA LEVEL FOURTH VOLTAGE |
| CTYM |
CONTACT ADJUSTMENT RANGE |
+90.00/+180.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CTHF |
CONTACT LOAD CURRENT RATING |
16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| AFDV |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS |
3.281 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
ARLEIGH BURKE CLASS DDG, TICONDEROGA CLASS CG (47), KIDD CLASS DDG, SPRUANCE CLASS DD (963), OHIO CLASS SSN (TRIDENT) SHIP. |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
440.0 AC AT SEA LEVEL THIRD VOLTAGE |
| CTYS |
CONTACT ADJUSTMENT TYPE |
EXTERNAL ACTUATION POINT SCREW |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
| CMLP |
THREAD QUANTITY PER INCH |
14 SINGLE THREADED HOLE |