5930-01-174-8593 ( MMP92159-1 , MMP92159-1 )

NSN Information
NSN FSC NIIN Item Name INC
5930-01-174-8593 5930 011748593 SWITCH,PRESSURE 0020
NSN Features
MRC Parameter Characteristics
AXGY MOUNTING METHOD BRACKET AND UNTHREADED HOLE
CTYC CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE, PRESET
CBBL FEATURES PROVIDED ELECTRICAL ACCESS PORT
CTZB CONTACT VOLTAGE RATING IN VOLTS 125.0 AC AT SEA LEVEL FIRST VOLTAGE
ADAU BODY HEIGHT 3.000 INCHES NOMINAL
FREQ FREQUENCY IN HERTZ 60.0 FIRST VOLTAGE
AARX INSIDE DIAMETER 0.250 INCHES NOMINAL SINGLE CONNECTION
ABKW OVERALL HEIGHT 5.750 INCHES NOMINAL
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, DOUBLE BREAK/DOUBLE MAKE, PERMANENT JUMPER, BOTH POSITIONS MAINTAINED
CTHF CONTACT LOAD CURRENT RATING 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE
ABHP OVERALL LENGTH 3.219 INCHES NOMINAL
CTZL PRESSURE CONNECTOR TYPE PLAIN, THREADED INTERNAL SINGLE CONNECTION
CSCF TERMINAL TYPE SCREW
FREQ FREQUENCY IN HERTZ 60.0 FOURTH VOLTAGE
CTYS CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT SCREW
CTHF CONTACT LOAD CURRENT RATING 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CTZB CONTACT VOLTAGE RATING IN VOLTS 125.0 DC AT SEA LEVEL FIFTH VOLTAGE
CTHF CONTACT LOAD CURRENT RATING 15.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CTZB CONTACT VOLTAGE RATING IN VOLTS 250.0 DC AT SEA LEVEL SIXTH VOLTAGE
CQYJ MOUNTING FACILITY PATTERN TWO POSITION DIAGONAL
AWTN OPERATING TEMP RATING 30.0 DEG FAHRENHEIT MINIMUM AND 110.0 DEG FAHRENHEIT MAXIMUM
CQGB CONTACT ACTION STIMULUS INCREASE
CTYM CONTACT ADJUSTMENT RANGE +100.00/+1500.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE
STYL STYLE DESIGNATOR RECTANGULAR
THSD THREAD SERIES DESIGNATOR NPT SINGLE PRESSURE CONNECTION
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.281 INCHES NOMINAL
CTZB CONTACT VOLTAGE RATING IN VOLTS 480.0 AC AT SEA LEVEL THIRD VOLTAGE
ABFE HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION SALT SPRAY RESISTANT AND FUNGUS RESISTANT
FREQ FREQUENCY IN HERTZ 60.0 THIRD VOLTAGE
CTHF CONTACT LOAD CURRENT RATING 1.0 AMPERES RESISTIVE LOAD FIFTH VOLTAGE
CTYX CONTACT STIMULUS RATING 320.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 245.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE
CTHF CONTACT LOAD CURRENT RATING 7.5 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
ABMK OVERALL WIDTH 2.370 INCHES NOMINAL
AFDV LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS 2.720 INCHES NOMINAL
FREQ FREQUENCY IN HERTZ 60.0 SECOND VOLTAGE
MEDA MEDIA FOR WHICH DESIGNED GAS, LIQUEFIED
CTZB CONTACT VOLTAGE RATING IN VOLTS 600.0 AC AT SEA LEVEL FOURTH VOLTAGE
CTHF CONTACT LOAD CURRENT RATING 500.0 MILLIAMPERES RESISTIVE LOAD SIXTH VOLTAGE
CQJB PROOF PRESSURE 7000.00 POUNDS PER SQUARE INCH GAGE
CTZB CONTACT VOLTAGE RATING IN VOLTS 250.0 AC AT SEA LEVEL SECOND VOLTAGE
AFDS LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 2.720 INCHES NOMINAL
AJZC PRESSURE SWITCH TYPE GAGE
CQJX NOMINAL THREAD SIZE 0.250 INCHES SINGLE PRESSURE CONNECTION
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
MMP92159-1 5RQL2 A 1 C 9X 6 ZZ
MMP92159-1 90598 A 9 3 6 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
MMP92159-1 5RQL2 DRS ENVIRONMENTAL SYSTEMS INC. A A
MMP92159-1 90598 ENGINEERED AIR SYSTEMS INC. A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 03/23/1 P 8536509065 0020
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DF N SF9EH-N F
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS Z 0 EA 0 U D
DF SMS Z 0 EA 0 U SF9EH-N F
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI