| CTZL |
PRESSURE CONNECTOR TYPE |
FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| CTYX |
CONTACT STIMULUS RATING |
10.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH |
| ABKV |
OUTSIDE DIAMETER |
0.438 INCHES NOMINAL SINGLE CONNECTION |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
DUSTPROOF AND FUNGUS RESISTANT AND HUMIDITY RESISTANT AND SALT SPRAY RESISTANT AND VIBRATION RESISTANT |
| ABHP |
OVERALL LENGTH |
2.290 INCHES NOMINAL |
| AWTN |
OPERATING TEMP RATING |
-65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
| MEDA |
MEDIA FOR WHICH DESIGNED |
LIQUID |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| ASDB |
WIDTH ACROSS FLATS |
1.000 INCHES NOMINAL |
| CSCC |
SENSING ELEMENT BURST PRESSURE |
1000.00 POUNDS PER SQUARE INCH GAGE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CQJB |
PROOF PRESSURE |
600.00 POUNDS PER SQUARE INCH GAGE |
| AAJD |
THREAD CLASS |
3A SINGLE PRESSURE CONNECTION |
| ADAQ |
BODY LENGTH |
1.200 INCHES MAXIMUM |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| AXGY |
MOUNTING METHOD |
INPUT PORT |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CTHF |
CONTACT LOAD CURRENT RATING |
7.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE AND 4.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE AND 2.5 AMPERES LAMP LOAD SINGLE VOLTAGE |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| CQJX |
NOMINAL THREAD SIZE |
0.438 INCHES SINGLE PRESSURE CONNECTION |
| AJZC |
PRESSURE SWITCH TYPE |
DIFFERENTIAL |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE PRESSURE CONNECTION |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT NOT ADJUSTABLE, MANUAL RESET |
| ADAV |
OVERALL DIAMETER |
1.000 INCHES NOMINAL |