5930-01-227-8262 ( TC-282-174 , TC-282-174 , 83D4010 ITEM 22 , 22-020-005 , 1334D00 IT 19 , 1336D00 FIND NO. 19 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5930-01-227-8262 | 5930 | 012278262 | SWITCH,THERMOSTATIC | 0045 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CTHF | CONTACT LOAD CURRENT RATING | 12.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| ABKW | OVERALL HEIGHT | 5.719 INCHES NOMINAL |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
| AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE AND SLOT |
| ABMK | OVERALL WIDTH | 1.875 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.688 INCHES NOMINAL |
| CSCF | TERMINAL TYPE | SCREW |
| CQGB | CONTACT ACTION STIMULUS | DECREASE |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| STYL | STYLE DESIGNATOR | RECTANGULAR |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CTHF | CONTACT LOAD CURRENT RATING | 6.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT DIAL |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.312 INCHES NOMINAL |
| ABTD | MOUNTING SLOT WIDTH | 0.250 INCHES NOMINAL |
| CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
| FREQ | FREQUENCY IN HERTZ | 60.0 SECOND VOLTAGE |
| ABHP | OVERALL LENGTH | 7.125 INCHES NOMINAL |
| AEVT | CAPILLARY TUBE LENGTH | 72.0 INCHES NOMINAL |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| TC-282-174 | 05624 | A | 2 | 5 | 5 | TX | |
| TC-282-174 | 65149 | A | 1 | C | AC | 6 | ZZ |
| 83D4010 ITEM 22 | 38450 | A | 2 | 3 | 5 | TX | |
| 22-020-005 | 38450 | A | 2 | 5 | 5 | ZZ | |
| 1334D00 IT 19 | 38450 | A | 2 | 5 | 5 | ZZ | |
| 1336D00 FIND NO. 19 | 38450 | A | 2 | 5 | 5 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| TC-282-174 | 05624 | GE AVIATION SYSTEMS LLC | F | A |
| TC-282-174 | 65149 | BARBER-COLMAN CO | A | A |
| 83D4010 ITEM 22 | 38450 | ENGINEERED COIL COMPANY | A | A |
| 22-020-005 | 38450 | ENGINEERED COIL COMPANY | A | A |
| 1334D00 IT 19 | 38450 | ENGINEERED COIL COMPANY | A | A |
| 1336D00 FIND NO. 19 | 38450 | ENGINEERED COIL COMPANY | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 03/09/1 | P | 9032100000 | 0045 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9B----- | N | |||
| GP | ------- | C | |||
| DS | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | P | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DN | SMS | D | 0 | EA | 0 | U | 9B----- | N | |
| GP | SMS | D | 0 | EA | 0 | U | ------- | C | |
| DS | SMS | D | 0 | EA | 0 | U | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061300 | X | 34410 | P | 658 | Z | 9 | A | H | Z | CIRCUIT BREAKER/SWITCH NOI |