| CTZL |
PRESSURE CONNECTOR TYPE |
FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| THSD |
THREAD SERIES DESIGNATOR |
UNJF SINGLE PRESSURE CONNECTION |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-S-9395/27 GOVERNMENT SPECIFICATION |
| ABKV |
OUTSIDE DIAMETER |
0.438 INCHES NOMINAL SINGLE CONNECTION |
| ADAV |
OVERALL DIAMETER |
1.150 INCHES MAXIMUM |
| CQGB |
CONTACT ACTION STIMULUS |
DECREASE |
| AWTN |
OPERATING TEMP RATING |
-65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
| CQJB |
PROOF PRESSURE |
120.00 POUNDS PER SQUARE INCH |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| AAJD |
THREAD CLASS |
3A SINGLE PRESSURE CONNECTION |
| ABHP |
OVERALL LENGTH |
2.950 INCHES NOMINAL |
| CTYX |
CONTACT STIMULUS RATING |
26.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 29.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
VIBRATION PROOF |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE AND 1.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
| CSCC |
SENSING ELEMENT BURST PRESSURE |
800.00 POUNDS PER SQUARE INCH |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-S-9395 SPECIFICATION |
| AXGY |
MOUNTING METHOD |
INPUT PORT |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| ADAQ |
BODY LENGTH |
2.175 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
5840-01-022-3002 RADAR SET |
| CQJX |
NOMINAL THREAD SIZE |
0.438 INCHES SINGLE PRESSURE CONNECTION |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS |