| CTZL |
PRESSURE CONNECTOR TYPE |
FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| AGAV |
END ITEM IDENTIFICATION |
5841-01-070-3859 RADIO,SURVEILLANCE |
| ABKV |
OUTSIDE DIAMETER |
0.438 INCHES NOMINAL SINGLE CONNECTION |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| ADAQ |
BODY LENGTH |
1.500 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| AAJD |
THREAD CLASS |
3A SINGLE PRESSURE CONNECTION |
| CQJB |
PROOF PRESSURE |
80.00 POUNDS PER SQUARE INCH ABSOLUTE |
| ADAV |
OVERALL DIAMETER |
0.680 INCHES NOMINAL |
| CTYX |
CONTACT STIMULUS RATING |
23.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH ABSOLUTE AND 20.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH ABSOLUTE |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| AXGY |
MOUNTING METHOD |
INPUT PORT |
| AASA |
THREAD LENGTH |
0.550 INCHES NOMINAL SINGLE PRESSURE CONNECTION |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| AJZC |
PRESSURE SWITCH TYPE |
ABSOLUTE |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
CORROSION RESISTANT AND MOISTURE RESISTANT |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| CQJX |
NOMINAL THREAD SIZE |
0.438 INCHES SINGLE PRESSURE CONNECTION |
| ASDB |
WIDTH ACROSS FLATS |
0.870 INCHES NOMINAL |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE PRESSURE CONNECTION |
| ABHP |
OVERALL LENGTH |
2.800 INCHES NOMINAL |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS |
| AWTN |
OPERATING TEMP RATING |
-40.0 DEG CELSIUS MINIMUM AND 75.0 DEG CELSIUS MAXIMUM |