5930-01-252-3222 ( MIL-S-24236/2 , M24236/2-BAHGGJ )

NSN Information
NSN FSC NIIN Item Name INC
5930-01-252-3222 5930 012523222 SWITCH,THERMOSTATIC 0045
NSN Features
MRC Parameter Characteristics
THSD THREAD SERIES DESIGNATOR UNF SINGLE THREADED BUSHING
CTZB CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE
AAJD THREAD CLASS 2A SINGLE THREADED BUSHING
STYL STYLE DESIGNATOR CYLINDRICAL W/FLANGE
AXGY MOUNTING METHOD THREADED BUSHING
ADAQ BODY LENGTH 1.500 INCHES NOMINAL
CTZB CONTACT VOLTAGE RATING IN VOLTS 28.0 DC AT SEA LEVEL SECOND VOLTAGE
AKBY TEMP SENSING ELEMENT TYPE IMMERSION WELL
AASA THREAD LENGTH 0.312 INCHES NOMINAL SINGLE THREADED BUSHING
CQGB CONTACT ACTION STIMULUS INCREASE
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-S-24236/2 GOVERNMENT SPECIFICATION
MEDA MEDIA FOR WHICH DESIGNED GAS OR LIQUID
ABHP OVERALL LENGTH 2.595 INCHES NOMINAL
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
ABPM BODY DIAMETER 0.670 NOMINAL CENTIMETERS
CTYC CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE
CTHF CONTACT LOAD CURRENT RATING 1.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE AND 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 0.5 AMPERES LAMP LOAD FIRST VOLTAGE
TEST TEST DATA DOCUMENT 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL
ASDB WIDTH ACROSS FLATS 0.990 INCHES MINIMUM AND 1.135 INCHES MAXIMUM
AWTN OPERATING TEMP RATING -75.0 DEG FAHRENHEIT MINIMUM AND 500.0 DEG FAHRENHEIT MAXIMUM
CSCF TERMINAL TYPE CONNECTOR, RECEPTACLE
CTYX CONTACT STIMULUS RATING 95.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 80.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CQJX NOMINAL THREAD SIZE 0.750 INCHES SINGLE THREADED BUSHING
AGAV END ITEM IDENTIFICATION 5864-01-008-6629 COUNTERMEASURES SET,SPECIAL PURPOSE
CTHF CONTACT LOAD CURRENT RATING 2.5 AMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
MIL-S-24236/2 81349 M 1 4 E TX
M24236/2-BAHGGJ 81349 M 2 2 E TX
Manufacturers
Part SKU Cage Manufacturer Type Status
MIL-S-24236/2 81349 MILITARY SPECIFICATIONS A M
M24236/2-BAHGGJ 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X A 04/01/1 P 9032100000 0045
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS N I
DA Z Q2200X- A
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DS SMS X 0 EA 0 U D
DA SMS X 0 EA 0 U Z Q2200X- A
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC